SSaLT Results for Billie Jean King Main Library (17645)
Room Surveyed:  Meeting Room A
   

   
Cellular Measurements from Load Test
Carrier Upload Speed Download Speed
FirstNet 5G 5.56 56.27
T-Mobile 5G 23.07 168.64
Verizon 5G 1.30 33.75
Ethernet (Speeds) 906.57 341.64
Ethernet (Port) Data Ports located in Floor plates in Room


Uploaded Files
File Description Upload Date Uploaded By
Room Picture2/9/2026Rafael Meza
Diagram2/9/2026Rafael Meza
Data Jack 1ELA-21 2/7/2026


Last Used (Election)
November 2024 General Election

 
ePulse Download Results
Carrier Result
AT&T Successful
T-Mobile 5G Successful
Verizon 5G Successful
Ethernet (WAN) Successful


Changes to Electrical
Add Generator
Add Spider Box
 
SSaLT Summary
Description Quantity
Max BMDs Supported (power) 320
Max BMDs Supported (outlets) 200
Max ePollBooks Supported 23
Site Survey Result Passed
Load Test Status Completed
Load Test Date 2/6/2026
Cellular Result Cell (3)
Ethernet Result Successful


Electrical Survey Summary
Description Value
Electrical Survey Date 2/6/2026
Available Amperage 280.00
Number of Working Outlets 42
Number of Dead Outlets 0
2 Prong (Type A) 15 Amp Outlets 0
2 Prong (Type A) 20 Amp Outlets 0
3 Prong (Type B) 15 Amp Outlets 0
3 Prong (Type B) 20 Amp Outlets 42
Electrical Surveyor Rafael Meza